Part Number Hot Search : 
CCF6054K TFS1220M FW233 M3FL20 BFR94 ER1601 LT1803 3BT48
Product Description
Full Text Search
 

To Download DNR120TS12 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 AC-DC
120-240 Watts DNR120-240TS Series
* * * * * * *
xppower.com
Rugged Design for Industrial Applications Up to 88% Typical Efficiency Wide Adjustment Range Full Power to 60 C Three Phase Operation Single Phase Operation -25 C to 70 C Operation
Specification
Input
* 340-575 VAC 3O (1O to 1O operation with 75% output derating), 480-820 VDC Input Frequency * 47-63 Hz Input Current * DNR120TS: 0.35 A at 500 VAC DNR240TS: 0.70 A at 500 VAC Inrush Current * 120 W 15 A typical at 500 VAC, cold start 240 W 20 A typical at 500 VAC, cold start Power Factor * 0.6 at 500 VAC input and nominal load Earth Leakage Current * 0.32 mA Input Voltage
General
Efficiency Isolation * See table * 3000 VAC Input to Output 1500 VAC Input to Ground 500 VAC Output to Ground * DNR120TS: 65 kHz typical DNR240TS: 25 kHz typical * DC ON indicator LED Green, DC LOW indicator LED Red DC OK: normally open relay on 24 V models * 210 kHrs to MIL-STD 217 F
Switching Frequency Signals
Output
Output Voltage Output Voltage Trim Initial Set Accuracy Minimum Load Start Up Delay Start Up Rise Time Hold Up Time Line Regulation Load Regulation Transient Response Ripple & Noise Overvoltage Protection Overload Protection Temperature Coefficient Current Share * * * * * * * * * * * * * * See table See table 1% No minimum load required <1000 ms <150 ms 20 ms min at 400 VAC 1% 1% (5% for units in parallel) 4% max deviation recovering to within 1% in 1 ms for 50% load change 100 mV pk-pk 20 MHz BW 120-145%, recycle input to reset Continuous current limit 0.02%/C
MTBF
Environmental
Operating Temperature * -25 C to 70 C, derate linearly from 60 C at 3.5%/C (see derating curve) Cooling * Convection-cooled Operating Humidity * 20-95% RH, non-condensing Storage Temperature * -25 C to +85 C Shock * 4 g peak, 22 ms on X, Y and Z axis Vibration * 10 to 500 Hz, 1 g rms on X, Y and Z axis
EMC & Safety
Emissions Harmonic Currents Voltage Flicker ESD Immunity Radiated Immunity EFT/Burst Surge Conducted Immunity Magnetic Field Dips & Interruptions * * * * * * * * * * EN55022, class B conducted & radiated EN61000-3-2, class A EN61000-3-3 EN61000-4-2, level 4 perf criteria A EN61000-4-3, level 3 perf criteria A EN61000-4-4, level 4 perf criteria A EN61000-4-5, level 3 perf criteria B EN61000-4-6, level 3 perf criteria A EN61000-4-8, level 4 perf criteria A EN61000-4-11, 30% 500 ms, 60% 200 ms, 100% 5000 ms Perf Criteria A, A, A * EN60950-1:2001, UL508, UL60950-1
* 2 units can be connected in parallel, DNR240TS only, total output derates by 10%
Safety Approvals
AC-DC
Models and Ratings
Output Voltage 12 V 24 V 24 V 48 V Notes
1. Reduce by 25% for single phase input operation.
DNR120-240TS
Output Current(1) 10.0 A 5.0 A 10.0 A 5.0 A Typical Efficiency 87% 88% 87% 88% Model Number DNR120TS12 DNR120TS24 DNR240TS24-I DNR240TS48-I
Output Voltage Trim 11.4-14.5 V 22.5-28.5 V 22.5-28.5 V 47.0-56.0 V
Mechanical Details
4.39 (111.3)
6 1
DC LO ON
0.3 (7.0)
DNR120TS
4.87 (123.6)
DNR240TS
DC LO ON
4.87 (123.6)
Single Parallel
1
4
1
4
4
1 5 6
AC Input 2.93 (74.3)
AC Input
DC Output
3.50 (89.0)
DC OK signal connector on underside
Notes
1. All dimensions in inches (mm). 2. Weight - DNR120TS: 1.76 lb (800 g) approx. DNR240TS: 2.43 lb (1100 g) approx. 3. Screw terminal: 10-24 AWG cable size. DC OK signal connector: 10-24 AWG cable 4. DC OK Relay 60 VDC at 300 mA 5. Allow 0.98" (25 mm) clearance all round for cooling
Pin Connections - AC Input Pin Designation 1 Ground 2 L1 3 L2 4 L3
Pin 1 2 3 4 5 6
Pin Connections - DC Output Designation -V -V +V +V DC OK* DC OK*
* Available on 24 V versions.
Derating Curves
DNR120-240TS 100
Load (%)
75
0 -25 Ambient Temp (C)
60
70
18-Nov-08


▲Up To Search▲   

 
Price & Availability of DNR120TS12

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X